Home  |  Contact  |  Sitemap  |  Chinese  |  CAS
Search: 
News
Location: Home > 旧网站归档- > News > Events
A novel coupled VM-PT cryocooler operating at liquid helium temperature
Author:
ArticleSource:
Update time: 2016-05-01
Close
Text Size: A A A
Print

This paper presents experimental results on a novel two-stage gas-coupled VM-PT cryocooler, which is a one-stage VM cooler coupled a pulse tube cooler. In order to reach temperatures below the critical point of helium-4, a one-stage coaxial pulse tube cryocooler was gas-coupled on the cold end of the former VM cryocooler. The low temperature inertance tube and room temperature gas reservoir were used as phase shifters. The influence of room temperature double-inlet was first investigated, and the results showed that it added excessive heat loss. Then the inertance tube, regenerator and the length of the pulse tube were researched experimentally. Especially, the DC flow, whose function is similar to the double-orifice, was experimentally studied, and shown to contribute about 0.2 K for the no-load temperature. The minimum no-load temperature of 4.4 K was obtained with a pressure ratio near 1.5, working frequency of 2.2 Hz, and average pressure of 1.73 MPa. 

Available online 27 April 2016

Copyright 2007-2015 All rights reserved. 29 Zhongguancun East Road, Haidian District, Beijing, 100190, PR China
Please send any comments or problems with this site to: lzhang@mail.ipc.ac.cn.